7.1. Terraced flats
Upgrade | Criteria and constraints | Cost (£) | ||
---|---|---|---|---|
Pre-1919 | 1919-1991 | Post-1992 | ||
Fabric upgrades | ||||
Individual dwelling measures | ||||
Loft insulation | For top floor only Usually top up Much more expensive if room-in-roof or flat roof |
775 | 604 | |
Internal wall insulation | Typically for pre-1919 Could be added to CWI Could be instead of CWI |
6,424 | 4,442 | |
Floor insulation | Ground floor only Suspended floor to 1983 More expensive for solid floor |
4,281 | 2,956 | |
Replacement windows | More expensive in conservation areas Secondary glazing may be cheaper in conservation areas Single glazing more common in older buildings Replacement of poor DG possible at any age |
3,740 | 3,267 | 3,386 |
Replacement external doors | More expensive in conservation areas | 600 | 600 | 600 |
General draught-proofing / air tightness | 112 | 75 | 84 | |
Individual dwellings subtotal | Without wall insulation | 5,226 - 8,732 | 4,546 - 6,898 | 4,071 - 4,071 |
With wall insulation | 11,650 - 15,157 | 8,988 - 11,340 | 4,071 - 4,071 | |
Communal measures | ||||
Cavity wall insulation | Jointly with other floors Typically for 1919 to 1983 |
426 | ||
External wall insulation | Jointly with other floor Typically for pre-1919 Could be added to CWI Not for conservation areas |
10245 | 8224 | |
Communal fabric subtotal | With wall insulation | 15,471 - 18,977 | 4,973 - 15,123 | 4,071 |
Heating system upgrades | ||||
Heating system size (kW) | 3.9 | 2.4 | 3.2 | |
Individual dwelling measures | ||||
Standard ASHP | Property 2 floors max Consent for external units |
6,000 - 10,000 | 6,000 - 10,000 | 6,000 - 10,000 |
Internal ASHP/Hybrid | Airing cupboard by external wall | 6,000 - 10,000 | 6,000 - 10,000 | 6,000 - 10,000 |
Direct electric heating | External space | 4,000 | 4,000 | 4,000 |
Smart storage heaters | 7,028 | 4,749 | 5,324 | |
Individual dwelling measures only totals | Without wall insulation | 9,226 - 18,732 | 8,546 - 16,898 | 8,071 - 14,071 |
With wall insulation | 15,650 - 25,157 | 12,988 - 21,340 | 8,071 - 14,071 | |
Overall range | All measures | 15,650 - 28,977 | 12,973 - 25,123 | 8,071 - 14,071 |
7.2. Four-in-a-block
Upgrade | Criteria and constraints | Cost (£) | ||
---|---|---|---|---|
Pre-1919 | 1919-1991 | Post-1992 | ||
Fabric upgrades | ||||
Individual dwelling measures | ||||
Loft insulation | For top floor only Usually top up Much more expensive if room-in-roof or flat roof |
712 | 581 | |
Internal wall insulation | Typically for pre-1919 Could be added to CWI Could be instead of CWI |
11,285 | 8,192 | |
Floor insulation | Ground floor only Suspended floor to 1983 More expensive for solid floor |
3,790 | 2,777 | |
Replacement windows | More expensive in conservation areas Secondary glazing may be cheaper in conservation areas Single glazing more common in older buildings Replacement of poor DG possible at any age |
4,902 | 4,163 | 4,164 |
Replacement external doors | More expensive in conservation areas | 1,200 | 1,200 | 1,200 |
General draught-proofing / air tightness | 200 | 144 | 144 | |
Individual dwellings subtotal | Without wall insulation | 7,013 – 10,092 | 6,088 – 8,284 | 5,507 |
With wall insulation | 18,298 – 21,377 | 14,279 – 16,475 | 5,507 | |
Communal measures | ||||
Cavity wall insulation | Jointly with other floors Typically for 1919 to 1983 |
813 | ||
External wall insulation | Jointly with other floor Typically for pre-1919 Could be added to CWI Not for conservation areas |
15,200 | 12,046 | |
Communal fabric subtotal | With wall insulation | 22,213 – 25,292 | 6,901 – 20,330 | 5,507 |
Heating system upgrades | ||||
Heating system size (kW) | 3.5 | 2.2 | 2.8 | |
Individual dwelling measures | ||||
Standard ASHP | Property 2 floors max Consent for external units |
6,000 – 10,000 | 6,000 – 10,000 | 6,000 – 10,000 |
Internal ASHP/Hybrid | Airing cupboard by external wall | 6,000 – 10,000 | 6,000 – 10,000 | 6,000 – 10,000 |
Direct electric heating | External space | 4,000 | 4,000 | 4,000 |
Smart storage heaters | 6,185 | 4,441 | 4,444 | |
Individual dwelling measures only totals | Without wall insulation | 11,013 – 20,092 | 10,088 – 18,284 | 9,507 – 15,507 |
With wall insulation | 22,298 – 31,377 | 18,279 – 26,475 | 9,507 – 15,507 | |
Overall range | With wall insulation | 22,298 – 35,292 | 14,901 – 30,330 | 9,507 – 15,507 |
7.3. Low/high-rise flats (no tower blocks)
Upgrade | Criteria and constraints | Cost (£) | ||
---|---|---|---|---|
Pre-1919 | 1919-1991 | Post-1992 | ||
Fabric upgrades | ||||
Individual dwelling measures | ||||
Loft insulation | For top floor only Usually top up Much more expensive if room-in-roof or flat roof |
605 | 561 | |
Internal wall insulation | Typically for pre-1919 Could be added to CWI Could be instead of CWI |
5,262 | 6,139 | |
Floor insulation | Ground floor only Suspended floor to 1983 More expensive for solid floor |
2,959 | 2,615 | |
Replacement windows | More expensive in conservation areas Secondary glazing may be cheaper in conservation areas Single glazing more common in older buildings Replacement of poor DG possible at any age |
3,463 | 3,672 | 4,048 |
General draught-proofing / air tightness | 90 | 106 | 135 | |
Individual dwellings subtotal | Without wall insulation | 4,158 – 6,512 | 4,339 – 6,393 | 4,183 |
With wall insulation | 9,420 – 11,775 | 10,478 – 12,532 | 4,183 | |
Communal measures | ||||
Cavity wall insulation | Jointly with other floors Typically for 1919 to 1983 |
602 | ||
External wall insulation | Jointly with other floor Typically for pre-1919 Could be added to CWI Not for conservation areas |
9,061 | 9,955 | |
Communal fabric subtotal | With wall insulation | 13,219 – 15,573 | 4,941 – 16,348 | 4,183 |
Heating system upgrades | ||||
Heating system size (kW) | 2.5 | 2.1 | 2.6 | |
Individual dwelling measures | ||||
Internal ASHP/Hybrid | Airing cupboard by external wall | 6,000 – 10,000 | 6,000 – 10,000 | 6,000 – 10,000 |
Direct electric heating | External space | 4,000 | 4,000 | 4,000 |
Smart storage heaters | 4,755 | 4,161 | 4,648 | |
Individual dwelling measures only totals | Without wall insulation | 8,158 – 16,512 | 8,339 – 16,393 | 8,183 – 14,183 |
With wall insulation | 13,420 – 21,775 | 14,478 – 22,532 | 8,183 – 14,183 | |
Communal heating system | ||||
Communal ASHP | 8,000 – 10,000 | 8,000 – 10,000 | 8,000 – 10,000 | |
Communal total | With wall insulation | 21,219 – 25,573 | 12,941 – 26,348 | 12,183 – 14,183 |
Overall range | With wall insulation | 13,420 – 25,573 | 12,941 – 26,348 | 8,183 – 14,183 |
7.4. Tower blocks
Upgrade | Criteria and constraints | Cost (£) | ||
---|---|---|---|---|
Pre-1919 | 1919-1991 | Post-1992 | ||
Fabric upgrades | ||||
Individual dwelling measures | ||||
Loft insulation | For top floor only Usually top up Much more expensive if room-in-roof or flat roof |
584 | ||
Internal wall insulation | Typically for pre-1919 Could be added to CWI Could be instead of CWI |
5,532 | ||
Floor insulation | Ground floor only Suspended floor to 1983 More expensive for solid floor |
2,797 | ||
Replacement windows | More expensive in conservation areas Secondary glazing may be cheaper in conservation areas Single glazing more common in older buildings Replacement of poor DG possible at any age |
3,527 | 3,971 | |
General draught-proofing / air tightness | 95 | 129 | ||
Individual dwellings subtotal | Without wall insulation | 4,206 – 6,419 | 4,100 | |
With wall insulation | 9,738 – 11,951 | 4,100 | ||
Communal measures | ||||
External wall insulation | Jointly with other floor (at least) Typically for pre-1919 Could be added to CWI Not for conservation areas |
9,335 | ||
Communal fabric subtotal | With wall insulation | 13,542 – 15,755 | 4,100 – 4,100 | |
Heating system upgrades | ||||
Heating system size (kW) | 1.9 | 2.6 | ||
Individual dwelling measures | ||||
Internal ASHP/Hybrid | Airing cupboard by external wall | 6,000 – 10,000 | 6,000 – 10,000 | |
Direct electric heating | External space | 4,000 | 4,000 | |
Smart storage heaters | 4,475 | 6,067 | ||
Individual dwelling measures only totals | Without wall insulation | 8,206 – 16,419 | 8,100 – 14,100 | |
With wall insulation | 13,738 – 21,951 | 8,100 – 14,100 | ||
Communal measures | ||||
Communal ASHP | 8,000 – 10,000 | 8,000 – 10,000 | ||
Communal total | With wall insulation | 21,542 – 25,755 | 12,100 – 14,100 | |
Overall range | With wall insulation | 13,738 – 25,755 | 8,100 – 14,100 |