High rise domestic buildings: inventory
Information on the construction and fire safety of high rise domestic buildings in Scotland.
Annex A
HRI Questionnaire
Disclaimer:
Where the provision of data highlights an issue with the building then it is the responsibility of the building owner to undertake remedial action. If, through analysis of this data, the Scottish Government becomes aware of the building issues which may be of interest to the relevant enforcement authorities then we may pass this on.
Updates are provided to the best awareness of those completing the ProcXed system.
Question number | Completion rate (percentage) [10] | ||
---|---|---|---|
1.1 | In what local authority is the building located? | Drop down 32 local authorities | 100% |
1.2 | Who is the building owner? | Drop down options: LA; RSL; private | 100% |
1.3 | What is the building address? | Split by Address line, city, post code | 100% (where at least a building name, first line of address or post code was given) |
Question number | Completion rate (percentage) | ||
---|---|---|---|
2.1 | When was the building completed? | Drop down: options by decade from 1950s-2010s (this format matches the original inventory) | 99% |
2.2 | What is the estimated remaining lifespan of the building? | Drop down, 5 year increments from 0 to 100+. i.e. 0,5,10,…100+ | 79% |
2.3 | What is the height of the floor of the topmost storey above ground level in metres? | Field for direct entry, limited to whole values from 18+. | 98% |
2.4 | How many storeys above ground level are in the building? | Field for direct entry, limited to whole values | 100% |
2.5 | What is the total number of flats in the building? | Field for direct entry, limited to whole values | 100% |
Question number | Completion rate (percentage) | ||
---|---|---|---|
3.1 | What is the construction type of the building? | Multiple responses checkbox, with notes option where specified: | 99% |
3.1.1 | If this is an LPS-type building, does it have a mains gas supply?? | Yes / No | 87% |
3.2 | Does the building have rendered External Wall Insulation (EWI)? | Yes / No | 99% |
3.3 | Does the building have any Aluminium Composite Panels | Yes / No | 100% |
3.3.1 | If yes, please identify type | Multiple response checkbox options, with notes option where specified: 1. Polyethylene (PE) 2. Fire retardant (FR) 3. A2 Limited combustibility 4. Other (specify in notes) |
98% |
3.4 | Does the building have any other type of external wall panels? | Yes / No | 98% |
3.4.1 | If yes, please identify type[11] | Multiple response checkbox options, with notes option where specified: 1. Masonry infill panels 2. Other metal composite panels 3. High pressure laminate boards 4. Stone 5. Slate 6. Granite 7. Terracotta Tiles 8. Solid Metal Panels 9. Rainscreen Insulation Board 10. Zinc 11. Concrete Panel 12. Other (specify in notes) |
97% |
3.5 | Are there any insulation materials exposed in the external wall cavity? | Yes / No | 97% |
3.5.1 | If yes, please identify type | Multiple response checkbox options, with notes option where specified: 1. Expanded polystyrene 2. Polyisocyanurate foam 3. Stone Wool 4. Phenolic foam 5. Other (specify in notes) |
86% |
Question number | Completion rate (percentage) | ||
---|---|---|---|
4.1 | How many escape stairs does the building have? | Enter whole number | 100% |
4.2 | Are fire doors fitted to flat entrances? | Yes - all / Yes - partial / No | 97% |
4.2.1 | If no, please provide more details | 92% | |
4.3 | Are fire doors fitted to escape stairs? | Yes - all / Yes - partial / No | 100% |
4.4 | Are there any outstanding defects that have been highlighted by SFRS through their operational assurance visits?* | Yes / No *This information will also be requested from SFRS | 100% |
4.4.1 | If yes, please provide more details | Free text | 99% |
4.5 | Is the building fitted with sprinklers or another form of automatic fire suppression? (note this does not include portable/ personal automatic fire suppression equipment) | Yes / No | 99% |
4.5.1 | If yes, please indicate type of system | Multiple response checkbox options, with notes option where specified: | 100% |
4.5.2 | If yes, please indicate locations where this suppression is installed. | Multiple response checkbox options, with notes option where specified: | 100% |