Approved products for use in the UK's public water supply
A list of the products approved for use in contact with drinking water in the UK.
PART A: CHEMICALS AND FILTER MEDIA
INTRODUCTION
The products listed in this section are for use by water undertakers in connection with public water supplies, and cover :-
- Chemicals that can be used for the treatment and disinfection of water intended for human consumption;
- Chemicals that can be used for the treatment of assets, eg surface disinfection; and
- Filter media used in the large scale filtration of water, but not part of specific units, eg cartridge filters, membrane filtration units etc.
Two series of relevant European Standards ( EN) have now been published -
- Chemicals used for treatment of water intended for human consumption
- Products used for treatment of water intended for human consumption
As a consequence of the introduction of these EN standards treatment chemicals or products that conform with an appropriate EN standard, and that are used in accordance with any specific national condition of use (see Annex 2, sections 2.1 and 2.2 respectively) may be used without the approval of the Authorities. These standards are published by the British Standards Institute( BSi) as BSEN Standards and are available through BSi.
Products that conform to an appropriate EN standard are not subject to the approval process and are no longer listed in this publication. When new appropriate EN standards are published, products currently listed and conform to the appropriate new EN standard, will be removed from this section and temporarily listed in Annex 1 table 1.6.2.
The products listed in this section have only been assessed for their safety for use in public water supplies by water undertakers, in accordance with the relevant Instructions for Use. These products have NOT been assessed for -
(a) their efficacy or fitness for purpose in respect of any use; or
(b) their suitability for use in building water systems, including in terms of their safety when used in such systems.
IMPORTANT NOTE
Where a product based on a treatment chemical meeting the requirements of a relevant EN standard also contains other ingredients, whether or not these other ingredients meet the requirements of relevant EN standards, a formal review of the product by DWI is required before use - see Sections 1.4 and 3 of Advice Sheet 3 - http://www.dwi.gov.uk/31/pdf/Advicesheet3.pdf
The following chemicals and products are either, not covered by a relevant EN standard, or do not conform fully to the scope and/or requirements of a published EN. For all of the chemicals and products listed, the following general condition of approval applies:
It is the responsibility of the water undertaker to ensure that
(a) the method and manner of use; and
(b) the purity of these chemicals and products
are such that, in the case of water for public supply, the water treated meets the requirements of the relevant regulations). Where appropriate, additional specific conditions of approval are listed against the chemical or product.
A.1 FLOCCULANTS AND COAGULANTS
A.1.1 Products based on tannin
The dose used must not exceed 10 mg l-1 of active material.
GE Betz Ltd
WS 330/11/2 Klaraid PC 4000
A.1.2 Products based on aluminium and iron
For these products the dose must not exceed 150 mg l-1 of the product as supplied.
Clinty Chemicals Ltd
DWI 56/4/151 Ferric Aluminium Sulfate
A.1.3 Products based on iron
High Chemicals ( UK) Ltd
DWI 56/4/753 Econofloc 11
DWI 56/4/471 Econofloc 15
A.1.4 Products based on polyacrylamide
For the products listed below the following conditions apply:-
(i) no batch must contain more than 0.025% of free acrylamide monomer based on the active polymer content
(ii) the dose must average no more than 0.25mg/l and never exceed 0.50 mg/l of the active polymer
(iii) an upper limit for the content of free acrylamide monomer must be stated by the supplier for every batch
(iv) the method used for the analysis for free acrylamide monomer is that published in the series "Methods for the Examination of Waters and Associated Materials" entitled "Determination of Acrylamide Monomer in Waters and Polymers 1987" ( HMSO 1988)Method number 115. ISBN 01175 2039X
Ciba UK plc
DWI 56/4/885 Magnafloc LT20
DWI 56/4/883 Magnafloc LT22- DWI
DWI 56/4/884 Magnafloc LT22S- DWI
DWI 56/4/886 Magnafloc LT25
DWI 56/4/887 Magnafloc LT27
Kemira Chemicals b.v
DWI 56/4/893 Superfloc A100 PWG
DWI 56/4/894 Superfloc A110 PWG
DWI 56/4/895 Superfloc A120 PWG
DWI 56/4/896 Superfloc A130 PWG
DWI 56/4/897 Superfloc A137 PWG
DWI 56/4/898 Superfloc A150 PWG
DWI 56/4/899 Superfloc C-492 PWG
DWI 56/4/900 Superfloc N100 PWG
DWI 56/4/901 Superfloc N300 PWG
A.1.5 Products based on polyamine
For the products listed below the following conditions apply:-
(i) the dose must average no more than 2.5 mg/l and never exceed 5.0 mg/l as the active polymer
(ii) no batch must contain more than 40 mg/kg 3-monochloro propane 1,2-diol
(iii) the analytical system used for determining the batch content must have a limit of detection no greater than 4mg/kg. Both estimates must have at least 10 degrees of freedom and have been determined from batches of analyses carried out on not less than five separate days
(iv) the supplier must state for every batch an upper limit for the content of 3-monochloro propane 1,2-diol
Ciba UK plc
DWI 56/4/888 Magnafloc LT31
DWI 56/4/889 Magnafloc LT32
Kemira Chemicals b.v
DWI 56/4/902 Superfloc C573
Nalco Europe b.v
DWI 56/4/905 1Nalco 71223
DWI 56/4/906 1Nalco 71225
1indicates products which also contain a coagulant based on aluminium
A.1.6 Products based on polyDADMAC (Polydiallyldimethyl ammonium chloride)
For the products listed below the following conditions apply:-
(i) the dose must not exceed 10 mg/l of active polymer
Ciba UK plc
DWI 56/4/890 Magnafloc LT35
DWI 56/4/891 Magnafloc LT37
DWI 56/4/892 Magnafloc LT38
Kemira Chemicals b.v
DWI 56/4/903 Superfloc C587
DWI 56/4/904 Superfloc C592
A.2 ADSORBENTS
The contact bed containing the product must be adequately backwashed in accordance with the Instructions for Use document and then rinsed with 5 bed volumes of water passed downflow to waste.
GEH Wasserchemie Gmbh
DWI 56/4/378 GEH ferric hydroxide
Lanxess Deutschland GmbH
DWI 56/4/496 Bayoxide E 33P
Purolite International Ltd
DWI 56/4/421 Macronet - MN200
A.3 ION EXCHANGE RESINS SYSTEMS
A.3.1 Ion exchange resins
Orica UK Ltd - Watercare Europe
DWI 56/4/550 MIEXDOC Resin
Purolite International Ltd
DWI 56/4/63 Purolite A520E nitrate selective anion exchange resin
Rohm and Haas ( UK) Ltd
DWI 56/4/758 AMBERLITE PWA5
DWI 56/4/63 IMACHP 336
DWI 56/4/63 IMACHP 555
A.3.2 Ion exchange resin based processes
BOC
DWI 56/4/467 IXL Process
A.4 DISINFESTATION, DISINFECTION OR CLEANING AGENTS OF WATERWORKS APPARATUS AND DISTRIBUTION SYSTEMS
During the approval process there is no evaluation of a product's effectiveness, only of its safety in use. An approval given in this publication does not certify that the UK Authorities are satisfied that that the product is effective, but only that it is safe for use in accordance with the Instructions for Use supplied.
The fact that a product is approved does not justify any claim about its effectiveness.
Permission or consent for disposal of any wastewater generated to a sewer or watercourse must be obtained from the relevant water Service Company,or Environment Agency in England and Wales or Scottish Environment Protection Agency ( SEPA) in Scotland as appropriate.
Aquabiotics Pty Ltd
DWI 56/4/642 BoreSaver Liquid
DWI 56/4/641 BoreSaver Ultra C
Carus Chemical Company
DWI 56/4/631 Carusol 20 Liquid Permanganates
DWI 56/4/631 Carusol 40 Liquid Permanganates
EPSCO Ltd
WS 34/1/144 Carela Bio-Des
WS 34/1/144 Carela Bio-Plus
DWI 56/4/437 Carela Bio-Plusforte
DWI 56/4/578 Carela Novopur
DWI 56/4/380 Carela RS 100
Floran Technologies Inc
DWI 56/4/754 Floran Biogrowth Remover/Floran Catalyst
DWI 56/4/754 Media Master/Floran Catalyst
Panton McLeod Ltd
DWI 56/4/212 PM33
DWI 56/4/212 PM55
DWI 56/4/212 PM88
Permacare - Membrane Separations Group
DWI 56/4/385 Resintreat
R. Spane GmbH
DWI 56/4/730 Carela FIX & DES
Tevan BV
DWI 56/4/844 TEVAN Panox
For this product the following applies:
This product shall be rinsed until the concentration of Hydrogen Peroxide is 0.1mg/l or less.
For the following products the following conditions apply:
Current approval for the use of products containing silver salts in relation to emergency disinfection of water intended for human consumption is subject to the following conditions of approval:
- the concentration of silver in the water does not exceed 80 µg l -1; and
- consumers are exposed to water containing silver for only as long as necessary to restore conventional treatment, and for no more than a total of 90 days in any period of a year.
These conditions ensure that there is only a limited exposure of the consumer to silver.
ROAM Chemie NV
DWI 56/4/573 Huwa-San TR50
Tevan BV
DWI 56/4/381 TEVANSIL
Water Treatment Products Ltd
DWI 56/4/211 Sanosil Super 25
A.5 DISINFECTION OR CLEANING AGENTS OF MEMBRANES
During the approval process there is no evaluation of a product's effectiveness, only of its safety in use. An approval given in this publication does not certify that the Authorities are satisfied that that the product is effective, but only that it is safe for use in accordance with the Instructions for Use supplied.
The fact that a product is approved does not justify any claim about its effectiveness.
Ashland Drew Industrial Division
DWI 56/4/473 AmeROyal 363
Atkinson Chemicals Ltd
DWI 56/4/495 Kinro 1020
DWI 56/4/495 Kinro 1020D
DWI 56/4/524 Kinro 1406
DWI 56/4/524 Kinro 1406N
DWI 56/4/375 Kintrol 556
DWI 56/4/375 Kintrol 556C
Avista Technologies ( UK) Ltd
DWI 56/4/458 Delro 35
DWI 56/4/582 Delro 40
DWI 56/4/737 RoClean 111
DWI 56/4/870 RoClean L403
DWI 56/4/800 RoClean L404
DWI 56/4/824 RoClean L607
DWI 56/4/746 RoClean P303
DWI 56/4/868 Vitec 2000
DWI 56/4/457 Vitec 3000
DWI 56/4/582 Vitec 4000
DWI 56/4/458 Vitec 5000
DWI 56/4/801 Vitec 7000
DWI 56/4/869 Vitec 7000a
GE Betz Ltd
DWI 56/4/388 Hypersperse MDC150
DWI 56/4/388 Hypersperse MDC220
Genesys International Ltd
DWI 56/4/664 Genesol 38
DWI 56/4/665 Genesol 40
DWI 56/4/577 Genesys HR
DWI 56/4/495 Genesys LF
DWI 56/4/783 Genesys LF60
DWI 56/4/781 Genesys LS
DWI 56/4/610 Genesys MG
DWI 56/4/593 Genesys SI
DWI 56/4/524 Genesys SW
Gulf Specialized Water Services Company
DWI 56/4/534 GulfChem GS300
DWI 56/4/534 GulfChem GS500
DWI 56/4/534 GulfChem GS510
DWI 56/4/534 GulfChem GS520
DWI 56/4/534 GulfChem GS530
Permacare - Membrane Separations Group
DWI 56/4/326 Permaclean 77
DWI 56/4/326 Permaclean 99
DWI 56/4/463 PermaTreat 191
DWI 56/4/385 Resintreat
Rohm and Haas ( UK) Ltd
DWI 56/4/481 Acumer 1100
DWI 56/4/481 Acumer 4035
DWI 56/4/481 Acumer 4450
DWI 56/4/481 Acumer 4800
Water Treatment Products Ltd
DWI 56/4/821 WTPRO 411
DWI 56/4/822 WTPRO 413
A.6 DISINFECTANTS FOR EMERGENCY USE
Disinfectants for emergency use are no longer approved and listed under the requirements of Regulation 31(4)(a). Guidance upon the choice and use of disinfectants in an emergency is provided in Advice Sheet 9 ( http://www.dwi.gov.uk/31/pdf/Advicesheet9.pdf).
Approvals of previously listed disinfectants for emergency use have been revoked - see Information Letter 08/2008 ( http://www.dwi.gov.uk/regs/infolett/2008/info0808.shtm)
A.7 PRODUCTS BASED ON TRADITIONAL CHEMICALS
A.7.1 Traditional Chemicals
The following traditional chemicals (not covered by a specific BSEN) are considered by DWI to be unobjectionable on health grounds for the treatment of water.
For products in this section the following general condition applies:
The method of use and the purity of these products shall be such that, in the case of water for public supply, the water so treated meets the requirements of the relevant Regulations.
Calcium chloride
Calcium sulphate
Citric acid (food grade) - for use only in cleaning of membranes
Crushed flint ( e.g. Flintag)
Ferrous chloride
Magnesium carbonate
Magnesium hydroxide
Magnesium oxide
Magnesium sulphate - use only for re-mineralisation with RO membrane systems
Magnetite (Iron oxide (Fe 3O 4))
Products supplied as mixture of magnesium hydroxide and magnesium oxide
Sodium chloride
Sodium sulphate
A.7.2 On-site electrolytic generation of chlorine ( OSEC)
Products in this section are not fully covered by EN 901 and must conform to the following conditions of use:
(i) the method of use and the purity of the output of these products shall be such that, in the case of water for public supply, the water so treated meets the requirements of the relevant Regulations, and
(ii) the treated water must not contain more than 700 µg/l chlorate.
Aztec Environmental Controls
WS 34/1/82 Sodium hypochlorite generated by the ElectroCell Process
Proton Water Services Ltd
DWI 56/4/717 PRO- SEC System
DWI 56/4/864 Selcoperm
Severn Trent Services Ltd
DWI 56/4/549 Clortec cell
Wallace and Tiernan Ltd
DWI 56/4/775 Sodium hypochlorite generated by the OSEC system
Waterman Environmental Services Ltd
DWI 56/4/545 MIOX Electrolytic Sodium Hypochlorite Generators
A.8 DISINFESTATION AGENTS
During the approval process there is no evaluation of a product's effectiveness, only of its safety in use. An approval given in this publication does not certify that the Authorities are satisfied that that the product is effective, but only that it is safe for use in accordance with the Instructions for Use supplied.
The fact that a product is approved does not justify any claim about its effectiveness.
Bournemouth and West Hampshire Water Plc
DWI 56/4/720 Permasect WT for use in disinfestation of mains
For this product the following conditions apply:
(i) the dose applied must not cause the average and maximum concentration of permethrin or pyrethrins in water to exceed 10 and 20 m g l -1 respectively;
(ii) the period of dosing should be kept to a minimum and must never exceed 7 days;
(iii) adequate account shall be taken of those water uses likely to be affected by thepresence of permethrin or pyrethrins in water;
(iv) any water company proposing to use the product must give prior notificationto the Authorities in accordance with agreed procedures; and
(v) permission or consent for disposal of any wastewater generated to a sewer orwater course must be obtained from the relevant water service company or Environment Agency in England and Wales or Scottish Environment Protection Agency ( SEPA) in Scotland , as appropriate.
DWI 56/4/720 Permasect WT for use in application to slow sand filters
For this product the following conditions apply:
(i) the dose must not exceed 100µg/l and the residual must not exceed 0.1µg/l in the treated water;
(ii) the period of dosing should be kept to a minimum and must never exceed more than once in a 28 day period;
(iii) prior to dosing, the water undertaker must establish that the filter bed to be dosed is intact and free from defects that would permit short-circuiting of normal flow pattern;
(iv) monitoring of permethrin in the final treated water entering supply must be carried out at daily intervals during the first 7 days following commencement of dosing; and
(v) permission or consent for disposal of any wastewater generated to a sewer or water course must be obtained from the relevant water service company orEnvironment Agency in England and Wales or Scottish Environment Protection Agency ( SEPA) in Scotland , as appropriate.
A.9 OTHER CHEMICALS
Lithium Salts
For this product the following condition applies:
The use of lithium salts for meter calibration in water mains is acceptable providing that the maximum concentration of lithium in water supplied to consumers does not exceed 0.10 mg l -1 at any time (the analytical method used for lithium determination should have an accuracy better than ±0.01 mg l -1 at 0.10 mg l -1)
Singleton Birch Ltd
For these products the following condition applies:
The final water should not exceed 1 NTU ( NTU=nephlometric turbidity unit)
DWI 56/4/518 Hydrogel 20
DWI 56/4/518 Hydrogel 30
DWI 56/4/518 Hydrogel 50
A.10 FILTER MEDIA
Dryden Aqua Ltd
DWI 56/4/382 Advance Filtration Media ( AFM)